วันศุกร์ที่ 25 กรกฎาคม พ.ศ. 2551

FN MAG 58






Fabrique National MAG-58:
The FN MAG is the standard medium machine gun of many NATO countries, including the USA and Great Britain. It fires the powerful 7.62 NATO cartridge, and although the effective accuracy is little more that 2200 feet, its effective range for support fire is at least twice that.
The MAG is of solid all-steel manufacture, and features a quickly interchangable barrel. In recent US army tests it became clear that the MAG was able to fire a average of 26,000 (!) rounds between failures under battlefield conditions. This makes it arguably the most reliable medium machine gun in existence. It was this reliability that was one of the deciding factors in the US army`s deciscion to purchase the MAG as their M240 series of machine guns, replacing the M60 machine gun.
The MAG is fed by means of a desintegrating 100 round belt.
Weight:23.7 lbs (10.85kg).
Caliber:7.62x51mm NATO (.308).
Barrel Length:27.8 inch (54.5 cm).
Overall Length:50.4 inches (126 cm).
Action:Gas operated .
Mode of Fire:Fully Automatic .
Rate of Fire:600 - 1000 Rounds per minute .
Range:2200 feet (660 meters).
Feed:100 round belt.
Cost:$ 2,495
Made in:Belgium, USA.
Special:Extremely reliable, good accuracy, great availability (NATO standard).

วันศุกร์ที่ 18 กรกฎาคม พ.ศ. 2551

SOLFWARE HVAC

AutoCAD DUCT SIZING program. 15Kb To view the Screen Capture, go to Randall C. Wilkinson's page.
WINDOWS DUCT SIZING program. 5Kb To view the Screen Capture, go to Randall C. Wilkinson's page.
DOS DUCT SIZING calculator. 49Kb A stand alone DOS program for sizing new heating and air conditioning ducts. Imagine an RPN calculator customized for sizing ducts. Customizable, mouse aware, runs on minimum hardware. Full documentation included. Written by Randall C Wilkinson in 1989 using QuickBASIC.
Windows PIPE SIZING program. 9Kb A windows application Written by Randall C Wilkinson for sizing new HVAC and plumbing (pressurized) pipes. Uses slider bars for input. Useful mainly for sizing new pipes, but can be used to calculate pressure drop through simple systems. Written with Visual Basic 3.0 and therefore requires VBRUN300.DLL in your WINDOWS\SYSTEM directory (available by FTP from microsoft).
PSYCHROMETRIC FUNCTIONS for microsoft Excel 5.0, 32Kb A library of Visual Basic functions written by Randall C. Wilkinson especially for Excel 5.0 to calculate properties of moist air. ZIP file contains library of functions and Sample XLS files showing state point calculations, mixing problems and a simple psychrometric chart.
BUILDING HEATING LOAD for microsoft Excel 5.0, 4.7Kb This is a spreadsheet by Randall C. Wilkinson to calculate approximate heating loads for a single zone.
PMTHERM V 1.23 a free program for psychrometrics. For documentation and history go to Paul Milligan's home page

วันอังคารที่ 15 กรกฎาคม พ.ศ. 2551

Commissioning jomchang villa F phuket



Jomchang PHUKET EE,SN,AC START-FINISH
VILLA F
LEVEL 6

1COMMISSIONING ELECTRICAL 16.7.51-17.7.51
2COMMISSIONING WATER SUPPLY 15.7.51 - 16.7.51
3COMMISSIONING AIR CON 10.8.51-13.8.51
LEVEL 5
1COMMISSIONING ELECTRICAL 20.7.51-21.7.51
2COMMISSIONING WATER SUPPLY 15.7.51-16.7.51
3COMMISSIONING AIR CON 10.8.51-13.8.51
LEVEL 4
1COMMISSIONING ELECTRICAL 24.7.51-25.7.51
2COMMISSIONING WATER SUPPLY 15.7.51-16.7.51
3COMMISSIONING AIR CON 10.8.51-13.8.51
LEVEL 3
1COMMISSIONING ELECTRICAL 30.7.51 - 31.7.51
2COMMISSIONING WATER SUPPLY 15.7.51-16.7.51
3COMMISSIONING AIR CON 10.8.51-13.8.51
GAS SYSTEM
GAS 5.8.51-6.8.51
1MAID KITCHEN
2MAIN KITCHEN

วันจันทร์ที่ 14 กรกฎาคม พ.ศ. 2551

JOMCHANG VILLA B 14.7.08
















Out of ser vice

Main electric in ampore KRATU is out of service 2 times.

วันศุกร์ที่ 11 กรกฎาคม พ.ศ. 2551

Air Change Rates in some typical Rooms and Buildings

The volume of fresh air required for proper ventilation is determined of the size and use of the space ventilated.

The table below can be used as an indication of recommended air changing rates in some common rooms and buildings.


Building / Room Air Change Rates- n - (AC/Hr.)


All spaces in general min 4
Attic spaces for cooling 12 - 15
Auditoriums 8 - 15
Banks 4 - 10
Barber Shops 6 - 10
Bars 20 - 30
Beauty Shops 6 - 10
Boiler rooms 15 - 20
Bowling Alleys 10 - 15
Cafeterias 12 - 15
Churches 8 - 15
Clubhouses 20 - 30
Cocktail Lounges 20 - 30
Computer Rooms 15 - 20
Court Houses 4 - 10
Dental Centers 8 - 12
Department Stores 6 - 10
Dining Halls 12 -15
Dining rooms hotels 5
Dress Shops 6 - 10
Drug Shops 6 - 10
Engine rooms 4 - 6
Factory buildings, ordinary 2 - 4
Factory buildings, fumes and moisture 10 - 15
Fire Stations 4 - 10
Foundries 15 - 20
Galvanizing plants 20 - 30
Garages repair 20 - 30
Garages storage 4 - 6
Homes, night cooling 10 - 18
Jewelry shops 6 - 10
Kitchens 15 - 60
Laundries 10 - 15
Libraries, public 4
Lunch Rooms 12 -15
Luncheonettes 12 -15
Nightclubs 20 - 30
Malls 6 - 10
Medical Centers 8 - 12
Medical Clinics 8 - 12
Medical Office 8 - 12
Mills, paper 15 - 20
Mills, textile general buildings 4
Mills, textile dyehouses 15 - 20
Municipal Buildings 4 - 10
Museums 12 -15
Offices, public 3
Offices, private 4
Police Stations 4 - 10
Post Offices 4 - 10
Precision Manufacturing 15 - 50
Pump rooms 5
Restaurants 8 - 12
Retail 6 - 10
School Classrooms 4 - 12
Shoe Shops 6 - 10
Shopping Centers 6 - 10
Shops, machine 5
Shops, paint 15 - 20
Shops, woodworking 5
Substation, electric 5 - 10
Supermarkets 4 - 10
Town Halls 4 - 10
Taverns 20 - 30
Theaters 8 - 15
Turbine rooms, electric 5 - 10
Warehouses 2
Waiting rooms, public 4

Note that in many cases local regulations and codes will govern the ventilation requirements.
The fresh air supply to a room can be calculated as
Q = n V (1)
where
Q = fresh air supply (ft3/h, m3/h)
n = air change rate (1/n)
V = volume of room (ft3, m3)
Example - Fresh Air Supply to Public Library
The fresh air supply to a public library with volume 1000 m3 can be calculated as
Q = 4 (1/h) 1000 (m3)
= 4000 m3/h